FRONT PANEL CUTOUT
TOP CUTOUT
33 3/4
(857)
22 1/2
(572)
35 1/2
(902)
2 13/16
(71)
4 7/8
(124)
3/4
(19)
5. Unit shall be accessible for servicing from bottom.
6. The name/rating information shall be accessible.
TO FABRICATE:
1. Layout cutout dimensions on countertop and control
panel as per drawing.
2. Layout and fabricate control panel holes in counter
apron using angles (supplied) as templates.
Note: If stiffening is used around perimeter of countertop
cutout, total thickness of stiffener plus top cannot exceed
3/16". Also, make certain stiffener design does not interfere
with operation of "ears" on Wellslok flange. Use of
additional stiffener will provide more strength around
countertop opening and will provide a more even seal.
3. Griddle shall be accessible for servicing from the bottom.
TO INSTALL: (See conditions of Acceptability).
1. Remove knob and screws holding the thermostats to
front panel. Remove grease drawer. Disconnect wire from
pilot lights. This will remove control panel from griddle. Do
NOT disconnect wires from thermostats.
2. Caulk underside periphery of griddle flange with a bead
of silicone adhesive/sealant. This will assure a more
effective seal between countertop and griddle gasket.
Lower thermostat through countertop opening and position
griddle on counter.
3. From underneath, insert screwdriver into "slots" on
patented Wellslok frame and twist "ears" (clockwise) to
secure flange tightly to countertop.
4. Remount the thermostats to control panel. Reconnect
pilot light wire to pilot light. CAUTION: Be extremely careful
the pilot light wires are replaced in their original order.
5. Connect service leads to terminal block in the outlet
box provided.
6. Slide grease drawer track forward and secure to
control panel. Check to see that wiring is routed properly
away from drawer track.
7. Secure control panel to counter apron. Be certain the
thermostat capillary tubing is clear of all hot terminals.
PHASE
AMPS
25.0
28.8
43.3
49.9
L3L2L1
UNIT TO THE NEAREST SURFACE
MINIMUM CLEARANCE REQUIRED FROM
9
(229)(50)
21
(25)
BOTTOMSIDEBACK
CLEARANCES
THE INSTALLATION OF RECOGNIZED COMPONENT UNITS
REQUIRES ADDITIONAL EVALUATIONS TO UNDERWRITERS
LABORATORIES INC. STANDARDS.
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:
1. This appliance shall be installed in an all metal counter
with suitable wiring and control enclosures conforming to
national and local electrical codes.
2. Electrical component temperatures, including wiring, within
and surrounding the appliance must be monitored in the end
use installation for suitability.
3. Electrical grounding of all dead metal parts must be
reliably connected to the grounding means of the appliance
and must comply with requirements outlined in the
appropriate Underwriters Laboratories Inc. classification,
national and local electrical codes.
4. Increased clearances are required if storage of
combustible materials is in close proximity to this appliance.
PRODUCT DIMENSIONSCUTOUT DETAILS
90°C
90°C8 AWG Cu
6 AWG Cu57.6
50.025.0
28.8
12000
12000208
240G-196
G-196
RATING
FIELD WIRING GAUGE
TEMP.
SINGLE
AMPS PER LINE 3 PHASE
WATTSVOLTSMODEL
ELECTRICAL
WELLS/BLOOMFIELD * VERDI, NV
MODEL G-196
BUILT-IN GRIDDLE
INSTALLATION INSTRUCTIONS
37110-1 REV (-)
INSTALLATION INSTRUCTIONS
8 AWG Cu
6 AWG Cu
3 PHASE 1 PHASE
12.521.7 90°C10 AWG Cu25.012.512000480G-196 10 AWG Cu
SEE CONDITIONS OF ACCEPTABILITY BELOW
UNIT MUST BE INSTALLED IN AN ALL METAL COUNTER
OUTLET BOX
1/4
(6)
24
(610)
18 3/8
(467)
6 1/4
(159)
34 1/2
(876)
7 3/4
(197)
35
(889)
23 9/16
(598)
36 1/2
(927)
INCHES
(MM)
Vue de la page 0